MHD COPPER CONDUCTOR for all kinds of overhead power transmission.

STANDARD: ASTM B-2 & B-B, NEMA WC-7, ICEA S-66-524

Cross-linked polyethylene insulated medium hard drawn copper conductors are to be used as jumper on electric distribution system.

Copper cable

Enhanced Fire Safety LSZH / CPR

Lighter Weight and Potentially Lower Cost (compared to Copper)

Resources for engineers

MHD COPPER CONDUCTOR Technical datasheet

MHD COPPER CONDUCTOR DoP

MHD COPPER CONDUCTOR

Technical specifications

Application

Medium Hard Drawn copper conductors are to be used as jumper on electric distribution system.

Construction

Conductor

MHD Copper conductor to ASTM B-2

Insulation

XLPE to NEMA WC-7

Standards / Compliance

Standards and approvals

  • ASTM B-2 & B-B
  • NEMA WC-7
  • ICEA S-66-524

Construction Products Regulation

  • MHD Copper conductor
  • ASTM B-2

Disclaimer

The information displayed on this website is provided for reference purposes only and is not legally binding. Specifications, values, and technical data may be subject to change without notice. To obtain verified and up-to-date technical data for a specific cable, please download Top Cable’s official Technical Specification in PDF format. The PDF document constitutes the sole authoritative source of product data.

Characteristics

Electrical performance

AAC has high electrical conductivity and low power loss, making it suitable for efficient short to medium-distance power distribution, but it is less strong than ACSR for long spans.

Thermal performance

All Aluminium Conductor (AAC) has good thermal performance, allowing it to operate efficiently under normal load conditions with effective heat dissipation, but it has limited high-temperature strength compared to composite conductors, making it best suited for standard low-to-medium temperature applications.

Fire performance

All Aluminium Conductor (AAC) has limited fire resistance; it can withstand normal operating temperatures but may lose strength and conductivity under high heat or fire conditions, so it is not designed for fire-resistant or emergency power applications.

Mechanical performance

**All Aluminium Conductor (AAC) has low to moderate mechanical strength, making it suitable for short-span overhead lines, but it is less resistant to tension, wind load, and long-distance sag compared to reinforced conductors like ACSR.**

Environmental performance

Chemical & Oil resistance: Acceptable.
UV Resistant: UNE 211605.
UV resistant according to EN 50618.
Water resistance: AD8 Submersion.

Installation conditions

Open Air.
Buried.
In conduit.

Other

Meter by meter marking.

Why choose our MHD COPPER CONDUCTOR

As cable manufacturers, we ensure cost-effective premium quality and lasting performance.

Our in-house labs guarantee rigorous cable quality, reliability, and standards compliance.

Global cable delivery solutions—expert logistics for seamless supply.

Full cable stock, ready for fast delivery- shortest lead times.
Largest European stockholding.

EPD-certified cables: Sustainable manufacturing for your Scope 3 success.

Expert, friendly and professional sales team offering a fast & efficient customer service. Global customers are welcome!

Need expert advice, a custom solution, or an RFQ?

Questions? We’ll help you find a solution.